Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Allowed values
Preset value
000003E8
h
Subindex
02
h
Name
Shutdown Power Idle Time
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
000003E8
h
Subindex
03
h
Name
Open Brake Delay Time
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
000003E8
h
Subindex
04
h
Name
Start Operation Delay Time
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Subindex
05
h
Name
PWM Frequency
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
between 0 and 2000 (7D0
h
)
Preset value
00000000
h
Subindex
06
h
Name
PWM Duty Cycle
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
0, between 2 and 100 (64
h
)
Preset value
00000000
h
Version: 1.0.1 / FIR-v1748
155