Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Object name
Homing On Block Configuration
Object Code
ARRAY
Data type
INTEGER32
Savable
yes, category: application
Access
PDO mapping
Allowed values
Preset value
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: The number of entries was changed
from 4 to 3.
Firmware version FIR-v1540: "Name" entry changed from "Period Of
Blocking" to "Block Detection time".
Firmware version FIR-v1614: "Data Type" entry changed from
"UNSIGNED32" to "INTEGER32".
Firmware version FIR-v1614: "Savable" entry changed from "no" to
"yes, category: application".
Firmware version FIR-v1614: "Data Type" entry changed from
"UNSIGNED32" to "INTEGER32".
Firmware version FIR-v1614: "Data Type" entry changed from
"UNSIGNED32" to "INTEGER32".
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
Minimum Current For Block Detection
Data type
INTEGER32
Access
read / write
PDO mapping
no
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 000004EC
h
•
PD4-E601L42-M-65-1: 000004EC
h
•
PD4-EB59CD-M-65-1: 000015E0
h
Subindex
02
h
Name
Block Detection Time
Version: 1.0.1 / FIR-v1748