Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Description
The ramp is only used when starting up. When the switch is reached, the motor immediately switches
to the lower speed; when the end position is reached, it immediately stops.
60A2h Jerk Factor
Function
This object contains the factor that is used for converting from user-defined jerk units. See chapter
User-defined units.
Object description
Index
60A2
h
Object name
Jerk Factor
Object Code
ARRAY
Data type
UNSIGNED32
Savable
yes, category: application
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1738-B501312
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
Numerator
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000001
h
Subindex
02
h
Name
Divisor
Data type
UNSIGNED32
Version: 1.0.1 / FIR-v1748
264