![NANOTEC PD4-E Technical Manual Download Page 191](http://html.mh-extra.com/html/nanotec/pd4-e/pd4-e_technical-manual_705149191.webp)
Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Access
read only
PDO mapping
RX-PDO
Allowed values
Preset value
0C
h
Subindex
01
h
Name
Position Loop, Proportional Gain (closed Loop)
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 00002710
h
•
PD4-E601L42-M-65-1: 00000800
h
•
PD4-EB59CD-M-65-1: 00007530
h
Subindex
02
h
Name
Position Loop, Integral Gain (closed Loop)
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Subindex
03
h
Name
Velocity Loop, Proportional Gain (closed Loop)
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 00004E20
h
•
PD4-E601L42-M-65-1: 00001B58
h
•
PD4-EB59CD-M-65-1: 0000EA60
h
Subindex
04
h
Name
Velocity Loop, Integral Gain (closed Loop)
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 00000064
h
•
PD4-E601L42-M-65-1: 00000004
h
•
PD4-EB59CD-M-65-1: 000001F4
h
Version: 1.0.1 / FIR-v1748
191