© by N&W GLOBAL VENDING S.p.A.
39
11 2008 3275 00
mAiNTENANCE OF FLuOrESCENT LAmPS
Fluorescent lamps are installed inside the machine (to
illuminate the aesthetic panel). Their life depends upon
the number of startups and the time of use.
lamps tend to be exhausted with the passing of time,
thus reducing their luminous efficiency.
It is recommended to replace exhausted fluorescent
lamps regularly or, anyway, to remove them from the
machines.
On replacing already- or almost-exhausted fluorescent
lamps, it is recommended to replace starters too.
Before replacing fluorescent lamps or any other de
-
vice of the lighting system, detach the supply cable
from the mains.
Exhausted fluorescent lamps contain noxious
gases; to avoid any negative consequence for the
environment and human health, lamps shall be
properly disposed of.
ELECTriC PANEL
the electric panel is accommodated in the compartment
beneath the refrigerated box. Fuses and the switch can
be directly accessed. remove the metal protection, to
access the connectors in the front of the electric panel.
Attention!!!
Before replacing any fuse, please detach the power
supply cable from the mains.
ACCESS TO THE COOLiNg uNiT
If you have to access the cooling unit from the machine
for any reason whatsoever, please act as follows:
detach the machine from the mains;
-
remove the counterdoor,
-
remove the metal cover intended to protect connectors.
-
remove the cooling unit
-
to reassemble, act in the reverse order.
Fig. 34
Relay board for compressor and door lamp
1-
Lamp reactors
2-
Transformer fuses
3-
Transformer
4-
Fig. 35
Actuation board
1-
Door switch
2-
Sales motor switch
3-
Protection metal cover
4-