39
An Err
o
r
Me
ssa
ge App
ear
s
T
roub
lesho
o
ting
5-1 An Error Message Appears
5. Troubleshooting
Error Message
Cause
Remedy
E01: KNIFE HOME ERROR
The knife is not at the upper limit
when the power switch is turned
on. (The power switch is turned off
while the knife is lowered.)
Press one of the cutting buttons,
and while this is pressed, press
another cutting button after 0.5
seconds or later.
E02: CLAMP HOME ERROR
The clamp is not at the upper limit
when the power switch is turned
on. (The knife is at the upper limit.)
Press the
key.
E03: BACKGAUGE ERROR
The problem of the home position-
ing switch.
Check the home positioning
switch.
E04: BACKGAUGE ERROR
The limit switch is activated.
Move the backgauge using the
or
button.
E05: BACKGAUGE ERROR
The encoder malfunctions. The
spindle of the backgauge does not
turn.
Call your local dealer.
E06: BACKGAUGE ERROR
The spindle is turned by hand.
Turn off the power switch and on
again.
The machine is influenced by
noise.
If this occurs frequently, call your
local dealer.
E14: COVER OPEN
The lower cover is open.
Close the lower cover.
E09: OUT OF RANGE
The cutting length out of range is
input.
Press the
key and input the
cutting length within the range.
E10: MEMORY ERROR
The program is not recalled cor-
rrectly.
Press the
key. However,
the data of the EEPROM may be
collapsed. If this occurs fre-
quently, replace the EEPROM.
PRESS CUTTER BUTTONS
The mechanical problem of the
clamp occurs:
The upper limit sensor and pulse
sensor malfunction.
Remove the cause and press the
cutting buttons.
Ent
Ent
Ent