Troubleshooting
Electrical Control System
117
2.3 Outdoor unit malfunction
For 18~60K:
Display
Malfunction or Protection
E1
Communication malfunction between indoor and outdoor units
F0
Overcurrent protection
F1
Ambient temperature sensor (T4) is malfunction
F2
Outdoor heat-exchanger temperature sensor (T3) is malfunction
F3
Discharge temperature sensor (T5) is malfunction
F4
Outdoor EEPROM is malfunction
F5
Outdoor fan speed has been out of control
P0
IPM module protection
P1
DC voltage too high or too low protection
P3
Protection of ultra-low ambient temperature
P4
Rotor position protection of compressor
J0
High temperature protection of evaporator
J1
High temperature protection of condenser
J2
High discharge temperature protection
J3
PFC module protection
J4
Communication error between outdoor main chip and compressor driven chip
J5
High pressure protection
J6
Low pressure protection
P7
IGBT sensor is malfunction
J8
AC power input voltage protection
In low ambient cooling mode, the LED displays
“
LC
”
or alternative displays between running frequency
and
“
LC
”
(each displays 0.5s)
Summary of Contents for MUCR-H6 Series
Page 15: ...Air Velocity Distributions Reference Data Indoor Units 13 30 42K Cooling Heating ...
Page 16: ...Air Velocity Distributions Reference Data 14 Indoor Units 48 60K Cooling Heating ...
Page 21: ...Field Wiring Indoor Units 19 10 Field Wiring ...
Page 30: ...Static Pressure 28 Indoor Units 5 Static Pressure MUCR 12 H6 MUCR 18 H6 ...
Page 31: ...Static Pressure Indoor Units 29 MUCR 24 H6 MUCR 30 H6 ...
Page 32: ...Static Pressure 30 Indoor Units MUCR 36 H6 MUCR 42 H6 MUCR 48 H6 MUCR 48 H6T MUCR 60 H6T ...
Page 41: ...Service Space Indoor Units 39 3 Service Space ...
Page 52: ...50 Indoor Units 10 Field Wiring ...
Page 61: ...Field Wiring Indoor Units 59 10 Field Wiring MUCSR 12 H6 MUCSR 18 H6 ...
Page 64: ...Dimensions 62 Outdoor Units Model Unit mm W D H W1 A B 48 60 952 415 1333 1045 634 404 ...
Page 95: ...Refrigerant pipe installation Installation 93 ...