3 AT Commands, S-Registers and Result Codes
Register Unit
Range
Default
Description
S6
seconds 2–65*
2*
Sets the time the modem will wait
after it goes off-hook before it be-
gins to dial the telephone number.
S7
seconds 1–255*
50*
Sets the time the modem will wait
for a carrier signal before aborting
a call. Also sets the wait for si-
lence time for the @ dial modifier.
S8
seconds 0–65
2
Sets the length of a pause caused
by a comma character in a dialing
command.
S10
100 ms
1–254
20
Sets how long a carrier signal
must be lost before the modem
disconnects.
S11
1 ms
50–150* 95*
Sets spacing and duration of dial-
ing tones.
S28
decimal
0, 1–255 1
0 disables, 1–255 enables V.34
modulation.
S30
1 minute 0–255
0
S30 specifies the length of time (in
minutes) that the modem waits
before disconnecting when no
data is sent or received. This
function is only applicable to
buffer mode. (Also see \T com-
mand.)
S35
decimal
0–1
0
0 disables, 1 enables the V.25 data
calling tone, which allows remote
data/fax/voice discrimination.
S36
decimal
{0,2}, {1,3} N/A
This register specifies the action
to take in the event of negotiation
{4,6}, {5,7}
failure when error control is se-
lected. (See S48.)
Summary of Contents for MultiModem MT5634ZPW-PCI
Page 1: ...Model Number MT5634ZPW PCI Owner s Manual...
Page 6: ...vi...
Page 7: ...Chapter 1 Introduction and Description...
Page 15: ...Chapter 2 Installation...
Page 32: ...MT5634ZPW PCI 32 Owner s Manual...
Page 33: ...Chapter 3 AT Commands S Registers and Result Codes...
Page 54: ...MT5634ZPW PCI 54 Owner s Manual...
Page 55: ...Chapter 4 Troubleshooting...
Page 65: ...Chapter 5 Warranty Service and Technical Support...
Page 75: ...Appendices...