![multicomp pro MP700852 User Manual Download Page 32](http://html1.mh-extra.com/html/multicomp-pro/mp700852/mp700852_user-manual_1854247032.webp)
Page <32>
V1.0
07/01/22
Newark.com/multicomp-pro
Farnell.com/multicomp-pro
sg.element14.com/b/multicomp-pro
5.17.4 [Chanel Power On Off]
Turn on or off channel power measurements. Press [Meas Setup] to pop up the channel power measurement parameter
settings soft menu. The channel power is used to measure the transmitter channel power, according to the user set the
channel bandwidth, through the linear power integration method to obtain the absolute value of the main channel power.
5.17.5 [OBW On Off]
Turn on or off the occupied bandwidth measurement. Press [Meas Setup] to pop up the parameter setting soft menu for
occupying the bandwidth measurement. Occupied Bandwidth is a measure of the bandwidth occupied by the transmitter
signal can be measured from the total power ratio within the in-band power span, with a default value of 99% (the user can
set this value).
5.17.6 [Pass-Fail►]
Enter the pass / fail measurement function soft menu. Pass / fail measurement has two modes of window measurement and
area measurement.
5.17.6.1 [Window Meas►]
Enter Window measurement soft menu.
1) [Window Meas On Off]
Turn on or off window measurement mode.
2) [Limit Line On Off]
Turns the amplitude line on or off, and the amplitude line turns on when the window measurement is on.
3) [Freq Line On Off]
Turns the frequency line on or off, and the frequency line turns on when the window measurement is on.
4) [Limit Set Up Low]
Used to edit the upper and lower limit on the amplitude line.
5) [Freq Set Start Stop]
Start and stop frequencies for scanning line for editing.
6) [Window Sweep On Off]
Turns window sweep on or off. When the window sweep is on, only the window formed by the intersection of the amplitude
line and the frequency line is scanned. The peripheral stops scanning; the full frequency is scanned when it is closed.
7) [Return]
Return to the previous menu.
5.17.6.2 [Limit Meas►]
Enter limit measurement soft menu.
1) [Limit Meas On Off]
Turn on or off limit measurement mode.
2) [Line Up On Off]
When the upper limit line is turned on or off, the upper limit line is opened by default when the area measurement is on.
3) [Line Low On Off]
When the lower limit line is turned on or off, the lower limit line is opened by default when the area measurement is on.
4) [Shift X/Y Freq Ampt]
Frequency:
For the actual measurement, the edited area as a whole superimposed on a frequency, so that it can implement
left or right shift, easy to measure. Does not affect the frequency and marker of the spectrum analyzer settings.
Amplitude:
The region has been edited on the whole superimposed on a degree, so that it can move up or down, easy to
measure. Does not affect the amplitude setting of the spectrum analyzer.