4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑ Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 120);
, preheat engine oil, if required.
Coolant circuit
Check coolant level (→ Page 129).
Coolant circuit
Heat engine coolant with coolant preheating unit.
Fuel prefilter
Drain water (→ Page 108);
Check if suction-side pressure indicated at the fuel prefilter is within the
limit (→ Page 107).
Engine control system
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 54).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 54).
MS15021/01E 2012-02 | Operation | 57