4.2 Engine – Preparations for putting into operation after
extended out-of-service periods (>3 months)
Preconditions
☑ Engine is stopped and starting disabled.
☑ MTU Fluids and Lubricants Specifications (A001061/..) are available.
Putting into operation after extended out-of-service periods (>3 months)
Item
Measure
Engine
Depreserve (→ MTU Fluids and Lubricants Specifications A001061/..).
Lube oil system
Check engine oil level (→ Page 120);
preheat engine oil, if required.
Bar engine with starting system.
Fuel prefilter
Fill with fuel (→ Page 111).
Fuel prefilter, pressure
gauge
Align adjustable pointer with position of pressure indicator (→ Page 107).
Fuel system
Vent (→ Page 103).
Raw water pump (if raw
water pump lies above the
water line)
Fill with water (approx. 3 – 4 liters).
Coolant circuit
If engine is out of service for more than one year, change engine coolant
(→ Page 130).
Coolant circuit
Check coolant level (→ Page 129).
Coolant circuit
Heat engine coolant with coolant preheating unit.
ECU
Check plug-in connections (→ Page 153).
Engine control system
Switch master switch to ON;
Press READY FOR OPERATION button (→ Page 54).
LOP
Press LAMP TEST illuminated button (→ Page 54).
56 | Operation | MS15021/01E 2012-02
TIM-ID: 0000002208 - 004