7.23 Accessories for (Electronic) Engine Governor / Control
System
7.23.1 Engine governor and connectors – Cleaning
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Connector pliers
0135315483
1
Isopropyl alcohol
X00058037
1
Cleaning engine governor and
connectors
1.
Remove heavy soiling from housing surface
with isopropyl alcohol.
2.
Remove dirt from surface of connectors (1),
connector sockets and shrink-formed com‐
ponents (2) using a cloth moistened with
isopropyl alcohol.
3.
Check legibility of cable labels. Clean or re‐
place illegible labels.
Cleaning heavily soiled connectors
on engine governor
1.
Use connector pliers (2) to disengage bayo‐
net union nut (4) and withdraw connector
(3).
2.
Clean connector housings, connector sock‐
et housings (1) and all contacts with iso‐
propyl alcohol.
3.
When connectors, sockets and all contacts
are dry: Fit connectors and check engine
governor plug connections (→ Page 153).
150 | Task Description | MS15021/01E 2012-02
TIM-ID: 0000000948 - 009