HP connections
1 Jacket pipe
2 HP line
3 O-ring
4 Union nut
5 Recess for O-ring
6 Thrust ring
7 Ball-type seal area
8 Leakage overflow bore
9 Thrust ring
10 Union nut
11 Internal pipe of HP line
12 External pipe of HP line
13 Union nut
14 Connecting piece
15 Snap ring
16 Thrust ring
17 Compensating washers
18 Leak fuel connection
19 Union nut
20 Thrust ring
The HP fuel line is sealed by the thrust ring (9).
If leakage in the area of the thrust ring (9) or the HP line (2) occurs, the emerging fuel is routed to the
leakage chamber.
The leak fuel is drained off without pressure via the leakage overflow bore (8). The leakage chamber is
sealed toward the outside by the O-rings (3).
This prevents leaking fuel from escaping.
The connection is confirmed as compliant with SOLAS by DNV and GL.
26 | General Information | MS15021/01E 2012-02
TIM-ID: 0000002179 - 003