7.18 Battery-Charging Generator
7.18.1 Battery-charging generator drive – Coupling condition check
Preconditions
☑ Engine shut down and starting disabled.
Checking condition of battery-
charging generator drive coupling
1.
Remove protective cover.
2.
Check resilient coupling for cracks and de‐
formation (arrow).
3.
Contact Service in case of severe deforma‐
tion or cracking.
4.
Install protective cover.
138 | Task Description | MS15021/01E 2012-02
TIM-ID: 0000007390 - 006