7.24 Emergency Instrumentation (Local Operating Panel)
7.24.1 LOP – Visual inspection
Preconditions
☑ Engine is stopped and starting disabled.
Preparatory steps
1.
If READY FOR OPERATION button is illuminated brightly, press switch briefly.
Result:
READY FOR OPERATION button returns to basic brightness.
2.
Switch master power switch to OFF.
3.
Disconnect battery in accordance with battery manufacturer's instructions.
Checking housing and internal
assemblies for secure seating
1.
Open LOP front door.
2.
Check securing screws (1, 3, 4, 7) for firm
seating. Tighten loose threaded connec‐
tions.
3.
Check internal assemblies for firm seating,
this applies in particular to printed circuit
board (2) and PIMs (5, 6). Tighten loose
threaded connections.
4.
Close LOP front door.
MS15021/01E 2012-02 | Task Description | 157