5.3 Starting the engine in manual mode (test run)
Preconditions
☑
Generator (if fitted) is not connected to network.
☑
External start interlock is not activated.
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Before cranking the engine with starter system, make sure that there are no persons in the engine's
danger zone.
WARNING
A high level of noise is produced when the engine is running.
Risk of hearing loss!
• Wear suitable hearing protection.
NOTICE
Re-starting the engine following an automatic safety shutdown.
Risk of severe engine damage!
• Before starting the engine, make sure the root cause of the safety shutdown was eliminated.
• If the root cause cannot be identified or eliminated, contact Service.
Preparation
Item
Action
Operating mode switch (if
fitted)
Change to manual mode.
Preheating pump (if fitted)
Switch on.
Starting the engine
Item
Action
Control cabinet, operator
station etc. (depending on
manufacturer)
If coolant temperature is
• > 40 °C (with preheating system), or
• > 5 °C (without preheating system):
Press start button.
• Automatic starting sequence is performed;
• Engine speed display instrument indicates increasing crankshaft speed;
• After the starting sequence is completed, engine is running at rated
speed.
Connecting the generator (if fitted) to network, engine warm-up procedure to
reach operating temperature
Item
Action
Control cabinet, operator
station etc. (depending on
manufacturer)
Close the generator circuit breaker.
Engine
Apply full load only after engine has reached operating temperature (coolant
temperature approx. 75 °C).
48 | Operation | MS15058/04E 2018-12