Engine model
Power
Frequency
Application group
20V4000G44F
140 kW/cyl.
50 Hz
3B, continuous operation, variable load, ICXN
20V4000G44LF
150 kW/cyl.
50 Hz
3E, standby power, overload capability according to
ICXN
20V4000G94F
154 kW/cyl.
50 Hz
3D, standby power, fuel stop power, IFN
20V4000G94LF
165 kW/cyl.
50 Hz
3D, standby power, fuel stop power, IFN
Load factor:
< 75 % (3B)
< 85 % (3D, 3E)
Operating hours:
No limit for operating hours (3B)
500 h per year or for the duration of an emergency (3D, 3E)
Time between major over-
haul:
30,000 h to 24,000 h (3B)
8,000 h or 18 years (3D, 3E)
Table 1: Applicability
© 2018 Copyright MTU Friedrichshafen GmbH
This publication is protected by copyright and may not be used in any way, whether in whole or in part, without the prior writ-
ten consent of MTU Friedrichshafen GmbH. This particularly applies to its reproduction, distribution, editing, translation, micro-
filming and storage or processing in electronic systems including databases and online services.
All information in this publication was the latest information available at the time of going to print. MTU Friedrichshafen GmbH
reserves the right to change, delete or supplement the information provided as and when required.
Summary of Contents for 20V4000G44F
Page 4: ......