7.
Drain remaining coolant at intercooler (ar-
row).
8.
Tighten drain valve to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Spindle
11 A/F
Tightening torque
12 Nm
9.
Close the remaining drain valves and screw in drain plugs with new sealing rings.
10.
Fit valve cover on filler neck and close it.