1.3 Gendrive engines – Intended use
Intended use
The product is intended for use in accordance with its contractually-defined purpose as described in the rele-
vant technical documents only.
Intended use entails operation:
• Within the admissible operating parameters in accordance with the (→ technical sales documents – prod-
uct data – TVU data)
• With fluids and lubricants approved by the manufacturer in accordance with the (→ Fluids and Lubricants
Specifications of the manufacturer)
• With preservation approved by the manufacturer in accordance with the (→ Preservation and Represerva-
tion Specifications of the manufacturer)
• With spare parts approved by the manufacturer in accordance with the (→ Spare Parts Catalog/MTU con-
tact/Service partner)
• In the original as-delivered configuration or in a configuration approved by the manufacturer in writing (al-
so applies to engine control/parameters)
• In compliance with all safety regulations and observance of all safety and warning notices in this manual
• In compliance with the maintenance work and intervals specified in the (→ Maintenance Schedule)
throughout the useful life of the product
• In compliance with the maintenance and repair instructions contained in this manual, in particular with
regard to the specified tightening torques
The product shall not be operated in explosive atmospheres unless it fulfills the conditions for such use and
approval has been granted.
The section below applies to applications deployed in regions under the jurisdiction of the EPA.
• Use of EPA Tier 2 and Tier 3 certified genset engines.
• EPA Tier 2 and Tier 3 certified genset engines may only be used in generator sets for stationary emergen-
cy applications. Non-emergency operation is limited to 100 hrs per year.
The engines may be used in fixed speed gensets only. Permanent limitation to a max. engine power of less
than 560 kW (e.g. by means of correspondingly low generator power) is not admissible.
Any other use, particularly misuse, is considered as being contrary to the intended purpose. Such improper
use increases the risk of injury and damage when working with the product. The manufacturer shall not be
held liable for any damage resulting from improper use.
The specifications of the manufacturer will be amended or supplemented as necessary. Prior to use, ensure
that the most recent version is available. The latest version can be found at:
• For drive systems: http://www.mtu-online.com
• For power generation: http://www.mtuonsiteenergy.com
Modifications or conversions
Unauthorized changes to the product breach the conditions concerning its intended use and compromise
safety.
Only modifications or conversions expressly authorized by the manufacturer are regarded as compliant in
this sense. The manufacturer shall not be held liable for any damage resulting from unauthorized modifica-
tions or conversions.