Number of cylinders
16
Coolant pump: Volumetric flow
A
m³/h
27
Pressure in cooling system, max.
L
bar
6.0
Pressure loss over mixture cooler (at nominal flow rate 8.56)
bar
0.4
Table 25: Coolant system (LT circuit, referenced to max. power without HT heat extraction)
Lube oil system (referenced to max. power without HT heat extraction)
Number of cylinders
16
Lube oil operating temperature after oil heat exchanger, from
R
°C
82
Lube oil operating temperature after oil heat exchanger, to
R
°C
90
Lube oil operating temperature after oil heat exchanger, warning
R
°C
93
Lube oil operating temperature after oil heat exchanger, engine shutdown
L
°C
97
Lube oil pressure after oil filter
bar
5.5
Lube oil pressure after oil filter, warning
bar
4.5
Lube oil pressure after oil filter, shutdown
L
bar
4.0
Table 26: Lube oil system (referenced to max. power without HT heat extraction)
Fuel system
Number of cylinders
16
Gas temperature before engine, min.
L
°C
See MTU
Fluids and
Lubricants
Specifica-
tions
Gas temperature before engine, max.
L
°C
See MTU
Fluids and
Lubricants
Specifica-
tions
Gas flow pressure before Tecjet, min.
L
mbar
See MTU
Fluids and
Lubricants
Specifica-
tions
Gas flow pressure before Tecjet, max.
L
mbar
See MTU
Fluids and
Lubricants
Specifica-
tions
Table 27: Fuel system
General operating data
Number of cylinders
16
Cold start capability: Air temperature (w/o starting aid, with preheating) -
(case C)
R
°C
15
Site condition (to case C): Engine coolant temperature
R
°C
40
32 | Product Summary | MS150121/00E 2015-07