1.4520.271 – Warning Missing Reset Signal
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Reset signal from crankshaft is
missing.
u
Check sensor B75, sensor distance and cabling; replace if
necessary.
1.4520.272 – Warn. Missing Camshaft Signal
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Missing camshaft signal for
ignition system.
u
Check sensor B 1.2, sensor distance and cabling; replace if
necessary.
1.4520.273 – SCR Fault Odd
Red alarm. Initiated by IC922.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart ignition.
1.4520.274 – SCR Fault Even
Red alarm. Initiated by IC922.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart ignition.
1.4520.275 – Odd Energy Level out of Range
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Specified energy level is beyond
the valid range.
u
Adjust value.
1.4520.276 – Even Energy Level out of Range
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Specified energy level is beyond
the valid range.
u
Adjust value.
1.4530.007 – Shutdown
Red alarm. Initiated by F-Series.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart F-Series.