4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 178);
Preheat engine oil if required.
Coolant system
Check coolant level (→ Page 194).
Coolant system
Heat engine coolant with coolant preheating unit.
Fuel prefilter
Drain (→ Page 157);
Check that suction-side pressure indicated at the fuel prefilter pressure gage
is within the limit (→ Page 156).
Engine Control System
Refer to automation system operating instructions.
EIM
Check plug connections (→ Page 221).
MS150066/02E 2013-02 | Operation | 87