10.
Connect filling pump to filling connection
(1 or 3) on the suction side of the filter.
11.
Open vent valve (2 or 4) and fill with fuel
until fuel emerges from the vent pipe (7 or
5).
12.
Close vent valve (2 or 4).
13.
Open rotary slide valve (6) a little (by ap-
prox. 30°) and open vent valve(s) (2 or 4),
until fuel emerges from the vent pipe (7 or
5).
14.
Close vent valve(s) (2 or 4).
15.
Turn rotary slide valve (6) back to locked
position.
MS150066/02E 2013-02 | Task Description | 163
TIM-ID: 0000012750 - 003