359 – AL Open Load Cylinder B9
ZKP-Number: 18.004.558
Cause
Corrective action
Disruption fault in injector
cabling to cylinder B9. Result:
Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
360 – AL Open Load Cylinder B10
ZKP-Number: 18.004.559
Cause
Corrective action
Disruption fault in injector
cabling to cylinder B10. Result:
Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
361 – AL Power Stage Low
ZKP-Number: 18.004.496
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop engine) is set,
engine is additionally stopped in
this case.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
362 – AL Injector Power Stage High
ZKP-Number: 18.004.497
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop engine) is set,
engine is additionally stopped in
this case.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
363 – AL Stop Power Stage
ZKP-Number: 18.004.560
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop engine) is set,
engine is additionally stopped in
this case.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
124 | Troubleshooting | MS150066/02E 2013-02
TIM-ID: 0000018389 - 002