Special unions
The following types of union are spray-proof in case of leakage even without covers and have been con-
firmed as being SOLAS-compliant by GL and DNV.
Plug-in pipe union
Design precludes lateral spray as the point of separation is shielded by the sleeve (4).
Only leak-off along the line is possible, the pressure is decreased significantly if an O-ring (3) defect
occurs.
The union is confirmed as being SOLAS-compliant by DNV and GL.
Plugs and sensors
Screw-in plugs (2) are sealed toward the outside either with a copper sealing ring (1), according to DIN,
or an O-ring (ISO).
The fluid must first pass the thread in case of a loose threaded union or faulty sealing ring (2).
The pressure is so greatly reduced by this and the faulty sealing ring (2) that any leakage is not under
pressure.