365 – AL Stop MV-Wiring Ground
ZKP-Number: 18.004.561
Cause
Corrective action
Injector cabling fault. If bit
"1.1020.021" (Power Stage
Failure: Stop engine) is set,
engine is additionally stopped in
this case. Possible causes:
1. Short circuit of positive
connection of one or more
injectors to ground
2. Short circuit of negative
connection of one or more
injectors to ground
u
Check wiring, replace wiring harness as necessary.
371 – AL Wiring TO 1
ZKP-Number: 18.004.634
Cause
Corrective action
Short circuit or wire break on
transistor output 1 (TO 1).
1. Check charger valve/cabling, repair as necessary.
2. Replace engine governor
372 – AL Wiring TO 2
ZKP-Number: 18.004.635
Cause
Corrective action
Short circuit or wire break on
transistor output 2 (TO 2).
1. Check air recirculation valve/cabling, repair as necessary
2. Replace engine governor
373 – AL Wiring TO 3
ZKP-Number: 18.004.636
Cause
Corrective action
Short circuit or wire break on
transistor output 3 (TO 3).
u
Check wiring of charger valve 2 (marine engine)
374 – AL Wiring TO 4
ZKP-Number: 18.004.637
Cause
Corrective action
Short circuit or wire break on
transistor output 4 (TO 4).
u
Check wiring of charger valve 3 (marine engine)
MS150066/02E 2013-02 | Troubleshooting | 125
TIM-ID: 0000018389 - 002