241 – SD T-Umblasen
ZKP-Number: 18.004.581
Cause
Corrective action
Recirculation temperature
sensor faulty; Short circuit or
wire break
1. Check sensor and cabling (B49), replace as necessary.
2. Error cleared after restarting the engine.
242 – SD T-Coolant (R)
ZKP-Number: 18.004.622
Cause
Corrective action
Redundant coolant temperature
sensor faulty; Short circuit or
wire break
1. Check sensor and cabling, replace as necessary.
2. Error cleared after restarting the engine.
244 – SD P-Lube Oil (R)
ZKP-Number: 18.004.621
Cause
Corrective action
Redundant lube oil pressure
sensor faulty; Short circuit or
wire break
1. Check sensor and cabling, replace as necessary.
2. Error cleared after restarting the engine.
301 – AL Timing Cylinder A1
ZKP-Number: 18.004.500
Cause
Corrective action
Time-of-flight measuring fault of
injector in cylinder A1: Time-of
flight measured value extremely
low or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
302 – AL Timing Cylinder A2
ZKP-Number: 18.004.501
Cause
Corrective action
Time-of-flight measuring fault of
injector in cylinder A2: Time-of
flight measured value extremely
low or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
MS150066/02E 2013-02 | Troubleshooting | 113
TIM-ID: 0000018389 - 002