RAW WATER CIRCUIT (open circuit)
Heat exchanger
engine-mounted
Heat exchanger
remote
Raw water pump: Inlet pressure, min.
L
bar
-0.4
-0.4
--
--
Raw water pump: Inlet pressure, max.
L
bar
1.0
1.0
--
--
Pressure loss in off-engine raw water sys-
tem, max.
L
bar
1.0
1.0
--
--
LUBE OIL SYSTEM
Heat exchanger
engine-mounted
Heat exchanger
remote
Lube oil operating temperature before en-
gine, from
R °C
83
83
83
83
Lube oil operating temperature before en-
gine, to
R °C
91
91
91
91
Lube oil operating pressure before engine,
from
R bar
5.3
5.3
5.3
5.3
Lube oil operating pressure before engine,
to
R bar
6.3
6.3
6.3
6.3
Lube oil operating pressure (low idle)
(meas. point: before engine)
R bar
2.5
2.5
2.5
2.5
FUEL SYSTEM
Heat exchanger
engine-mounted
Heat exchanger
remote
Fuel pressure at engine inlet connection,
min. (when engine is starting)
L
bar
-0.1
-0.1
-0.1
-0.1
Fuel pressure at engine inlet connection,
min. (during engine operation)
L
bar
-0.3
-0.3
-0.3
-0.3
Fuel pressure at engine inlet connection,
max. (when engine is starting)
L
bar
1.5
1.5
1.5
1.5
Fuel supply flow, max.
A Liters/
min
GENERAL OPERATING DATA
Heat exchanger
engine-mounted
Heat exchanger
remote
Firing speed, from
R rpm
80
80
80
80
Firing speed, to
R rpm
120
120
120
120
STARTER (electric)
Heat exchanger
engine-mounted
Heat exchanger
remote
Rated starter voltage (standard design)
R V=
24
24
24
24
MS150066/02E 2013-02 | Technical Data | 75