Diagram 12V-Two crankshaft
positions
Diagram 16V-Two crankshaft
positions
1 Cylinder A1 is in firing TDC
2 Cylinder A1 is in overlap TDC
I Inlet valve
X Exhaust valve
Checking valve clearance at two crankshaft positions
1.
Check TDC position of piston in cylinder A1:
• If the rocker arms are not under load on cylinder A1, the piston is in firing TDC.
• If the rocker arms are under load on cylinder A1, the piston is in overlap TDC.
2.
Check valve clearance with cold engine:
• Inlet valves (long rocker arm) = 0.3 mm
• Exhaust valves (short rocker arm) = 0.5 mm
3.
Check all valve clearances in two crankshaft positions (firing and overlap TDC for cylinder A1) as per
diagram.
4.
Use feeler gauge to determine the distance between valve bridge and rocker arm.
5.
If the deviation from the reference value exceeds 0.1 mm, adjust valve clearance.
MS150033/04E 2012-07 | Task Description | 149
TIM-ID: 0000004368 - 002