184 – AL CAN PU-Data Flash Error
ZKP-Number:
Red alarm.
Associated parameter 2.0500.684
Cause
Corrective action
A programming error occurred
when attempting to copy a
received PU data module into
the Flash module.
u
Contact Service (configuration fault).
186 – AL CAN1 Bus Off
ZKP-Number:
Yellow alarm.
Associated parameter 2.0500.686
Cause
Corrective action
CAN controller 1 is in “Bus-Off”
status. Automatic switching to
CAN bus 2. Bus users (ECU,
SAM or EMU) faulty.
u
Check operation of nodes and cabling.
187 – AL CAN1 Error Passive
ZKP-Number:
Yellow alarm.
Associated parameter 2.0500.687
Cause
Corrective action
CAN controller 1 has signaled a
warning. Bus nodes (ECU, SAM
or EMU) are faulty.
u
Check operation of nodes and cabling.
188 – AL CAN2 Bus Off
ZKP-Number:
Yellow alarm.
Associated parameter 2.0500.688
Cause
Corrective action
CAN controller 2 is in “Bus-Off”
status. Automatic switching to
CAN bus 1. Bus users (ECU,
SAM or EMU) faulty.
u
Check operation of nodes and cabling.
MS150033/04E 2012-07 | Troubleshooting | 113
TIM-ID: 0000017544 - 001