- 34 -
3.7.6 Decode Timeout
[TOTALLIM]
If the reader cannot decode a symbol successfully within the timeout, the reader
will stop decoding. In case the reader takes a long time to decode symbols which
contain a large amount of data, the timeout should be set longer. On the other
hand, in case the data amout is small, the timeout can be set short.
3.7.7 Sensitivity against brightness
[VSENSE]
The value of the sensitivity should be set higher in case the reader tends to miss
the object coming into the field of view. On the other hand, the value should be set
lower in case the reader is highly sensitive to detect motion change of the object.
3.7.8 Double-read prevention
[LFVERIFY]
When the reader reads the same symbol again within the specified time, the
second read will be ignored.
3.7.9 Double-read prevention time
[LFVWAIT]
This setting is for LFVERIFY.
3.7.10 Illumination
setting with Autosense Mode
[LFLIGHT]
The reader flashes the internal illumination in Autosense Mode if this setting is
enabled.
3.7.11
Output the status of Autosense Mode
?LF[CR]
: Output the status of Autosense Mode
(Example of output)
******** STATUS ******** TFIR-31LAN
LFMOVELIM=2 (0:100ms 1:300ms 2:500ms 3:1000ms
4:1500ms 5:2000ms 6:2500ms 7:3000ms)
LFVERIFY=1 (0:OFF 1:ON) LFVWAIT=6 (x500ms 1-40)
LFLIGHT=1(0:OFF 1:ON)
VSENS=2 (0-4)
********* END ********** TFIR-31LAN
System version = M21C-V1.0a
Decode version = M21A-V1.0a