- 98 -
■
Is ITF set to a fixed length?
When using ITF (Interleaved 2 of 5) it is possible that the number of digits read
will be less than the actual digits encoded in the barcode. We recommend
setting the specific digit length for ITF.
10.3 Fail to communicate through TCP/IP protocol
Fail to communicate through TCP/IP protocol due to accidental unplug/plugin of
the LAN cable while the reader is in working mode.
■
Retry the connection process after disconnection.
To recover the connection, send the command “discon” through RS232C
interface for forced termination, and then retry the connection.
10.4 After Good Read, the reader emits 7 short beeps a few seconds later.
Communication error can be caused by the following reasons:
- The reader is set to COMFROM=0 or 2, but a serial cable is not connected.
- The reader is set to COMFROM=1 or 2, but a LAN cable is not connected.