NOTICE
The generated linearization might deviate from the linearity tolerances re-
garding different environmental conditions. In addition, the use of a dif-
ferent position magnet or more position magnets may cause differences.
For RP5 PROFINET sensors with the U-magnet applies:
• Install the magnet until the marking on the magnet points to the
sensor electronics housing.
• The marking on the magnet points to the same direction as the
elongated status LED in the lid of the sensor electronics housing.
Fig. 21: Magnet alignment of U-magnet for RP5 PROFINET with internal linearization
ar in
E on at d stat s E
Fig. 22: Magnet alignment of magnet slider for RP5 PROFINET with internal linearization
Fig. 23: Replacement of the base unit (e.g. RH5 sensor), part 1
Base unit
Sensor electronics housing
Tube with inner sensor element
1. Loosen the screws.
3 × socket head screw
M4 (A/F 2.5)
2. Pull out the base unit.
4.6 Replacement of sensor
The base unit of the sensor model RH5-B is replaceable as shown
in Fig. 23 and Fig. 24 for the sensor designs »M«, »S« and »T«. The
sensor can be replaced without interrupting the hydraulic circuit.
For RP5 PROFINET sensors with magnet slider applies:
•
1
Install the magnet sliders "S", "N" and "G" until the additional hole
in the magnet points towards the sensor electronics housing.
•
2
Install the magnet slider "V" until the joint points to the end of the
profile.
The internal linearization of the sensor is carried out under the
following conditions:
• Supply v24 VDC ±0.5
• Operating time > 30 min
• No shock and no vibration
• Eccentricity of the position magnet to central axis
of the sensor < 0.1 mm
dditiona or