SECTION 7
PREVENTATIVE MAINTENANCE
7.1
First 100 Hours
Change the pump lubrication oil filters every 25 hours for the first 100 hours of run time.
Thoroughly clean the pump lubrication oil suction strainer after the first 50 hours and 100 hours
operation.
Change the pump lubrication oil after the first 100 hours of operation, and clean the reservoir.
7.2
Daily Preventative Maintenance
Check the fluid level in the lubrication oil reservoir, drain off water, and service magnet.
Check the fluid level in the fluid end plunger lubrication reservoir.
Check the plunger pump for fluid leaks.
Check the pump lubrication oil system for leaks.
Check the fluid end plunger lubrication system for leaks.
Check the supercharge piping for leaks.
Check the fluid end bolts, see
Section 6.1.5
.
7.3
Weekly Maintenance
Check all items on “daily” list.
Check all valves, inserts, valve seats, and springs.
Check all discharge and suction valve cover seals.
Check suction pulsation dampener for correct pre-charge if applicable.
7.4
Every 100 Hours
Check all items on “daily” and “weekly” lists.
Check all plunger pump-mounting bolts to ensure that they are tight.
Change pump lubrication oil filters.
Check all supplies needed for routine maintenance, such as o-rings, fluid seals, valves, valve inserts,
valve seats, valve springs, packing, oil seals, filter elements, etc.
7.5
Every 250 Hours
Check all items on “daily,” “weekly,” and “100 hours” list.
Revision K 03/12/2019
MSI - A Division of Dixie Iron Works, Ltd. All rights reserved.
Page 41