6.3 PARTS SUBJECT TO MAINTENANCE
Maintenance shall be carried out with the Exhauster set out of service for replacement of damaged or worn
parts. The Exhauster does not require frequent maintenance. If compressed air does not meet indicated
requirements, the following could get damaged:
1. Pressure
regulator
2. Solenoid
valve
3. Filter
cartridge
4. Dedusting
device
Should cartridge fail and break, this could damage the turbine unit (5) and the silencer (6).
1) Remove the regulator:
•
Close air feed;
•
Release any residual air by opening the con-
densate drain cock;
•
Disconnect the lines, loosen and remove the
regulator;
•
Clean/change and refit the regulator;
•
Restore 5 bar pressure.
2) Replace solenoid valve if it jams. Change as fol-
lows:
•
Close air feed;
•
Release any residual air by opening the con-
densate drain cock;
•
Remove the connector by undoing the retain-
ing screw;
•
Remove the connecting tube and loosen the
solenoid valve;
•
Clean and/or change the solenoid valve;
•
Connect the connector and reconnect the
tubes.