Eco 40-55-75 manual revision 01/10
8
3.6 STOP CONTROLS
The Exhauster stop controls are:
•
main power cut-out by Main Switch (to set unit out of service located on control panel installed by the
Customer);
•
Rotating knife switch incorporated in
power control panel
that, when activated, cuts power to both
auxiliary and power circuits;
•
Controlled stop due to opening of the run enable auxiliary contact (e.g. suction mouthpiece Open /
Closed).
3.7 SAFE WORKING PROCEDURES
The Exhauster design features aim at eliminating all risks connected to its use.
The residual risks involved in operating mode are:
•
risks connected with the use of pneumatic energy;
•
risks connected with the use of electric energy;
•
risks of possible contact with product removed by suction;
•
risks of possible contact with hot surfaces.
To limit the consequences of such dangers as much as possible, it is important to comply with the following
rules:
•
Ensure that air supply pressure is available and set to specified value:
max. 10 bars
;
•
Do not start the Exhauster before checking the correct installation and parameters set at operator
panel; this can be done by running a cycle with no product to be taken in by exhauster;
•
Wear the personal protection gear suitable for the product in use;
•
Wear clothes with close-fitting sleeves.
3.8 RESIDUAL RISKS
During the normal suction cycle and during maintenance, the Operators can run some residual risks that
can not be completely avoided, due to the type of operation being performed, such as danger of
electrocution, noise and contact with hot surfaces (indicated by suitable warning plate).
3.9 NAMEPLATES
Table 3.9A - Types of Nameplates
Nameplates on the Exhauster fig.3.9.A
Nameplate
“A”
Nameplate
“B”
Nameplate
“C”
Via R. Morandi, 93 - 40060 TO SCAN ELLA
BO LO GN A ITALY
Tel. 0542-673488 Fax 0542-672065
MO D.
KW
A
MASSA
Kg
VO LTS
Hz
M /h
3
Mbar
MATRICO LA N .
MESE
AN N O
CO STRUZ IO N E
200
Nameplate
“D”
T>55°C
1
2
CONDENSATE
COCK
DRAIN
WARNING:
CONNECT TO
DRY COMPRESSED AIR
TAKE
OUT TO
ENVIRONMENT THE
EXHAUSTER
AIR OUTLET
THE MACHINE WAS
DESIGNED TO
REMOVE DUST
DERIVING FROM SANDING
PRIMER,
FILLER/SURFACER AND
NOTHING ELSE
Nameplate
“E”
Nameplate
“F”
Nameplate
“G”
Summary of Contents for CA Eco 40
Page 22: ...Eco 40 55 75 manual revision 01 10 22 Electric circuit diagram Eco 40 ...
Page 23: ...23 Eco 40 55 75 manual revision 01 10 Eco 40 ...
Page 24: ...Eco 40 55 75 manual revision 01 10 24 Eco 55 75 ...
Page 25: ...25 Eco 40 55 75 manual revision 01 10 Eco 55 75 ...
Page 26: ...Eco 40 55 75 manual revision 01 10 26 Eco 55 75 Eco 40 ...
Page 27: ...27 Eco 40 55 75 manual revision 01 10 ...
Page 33: ...33 Eco 40 55 75 manual revision 01 10 Date Operation description Signature ...