Decommissioning
ALTAIR io360
US
9
Decommissioning
9.1
Detector
9.1.1 Powering Down
(1) Hold the button for approximately 3 seconds.
The detector turns off.
(2) Follow the steps in section 8.8 "Batteries" to remove and store batteries.
(3) Wrap battery terminals with electrical tape for storage.
(4) Assembly front and back housings together.
9.1.2 Reset Network Features
The user can reset network features via the app:
• Disconnect from HUB
• Detector location
• Password
• Resetting the detector to a blank network configuration
Follow instructions in section 4.2 "Connecting a Network" to interface with the app.
9.1.3 Factory Reset
Factory reset is an optional decommissioning step and can only be performed during detector power on.
9.1.4 Storage Conditions
When not in use, store the detector in a safe, dry place between 18 °C (64 °F) and 30 °C (86 °F). The relative
humidity range of 15 % - 90 % relative humidity, non-condensing environment.
For extended storage, remove batteries and store separately in a safe, dry place.
(1) Turn on the detector.
To perform factory reset, during power up:
(2) Hold the button for approximately 12 seconds and release the button
when the display says Reset.
(3) Continue to hold the button to not perform factory reset.