![MPE DP SERIES II Operating And Service Manual Download Page 93](http://html1.mh-extra.com/html/mpe/dp-series-ii/dp-series-ii_operating-and-service-manual_1843048093.webp)
The query command, INTE? returns the status of external interlock.
Command Syntax:
[CONFigure]:INTErlock <bool>
Parameters:
0 | OFF | 1 | ON
Examples:
CONF:INTE ON
INTE 0
Query Syntax:
[CONFigure]:INTErlock?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.5 CONF:SETPT
This command sets the operational mode of the power supply: rotary, keypad, external, or remote.
Configuring the power supply for keypad is only valid for D Version front panels.
Command Syntax:
[CONFigure]:SETPT <NR1>
Parameters:
0 = ROTARY, 1 = KEYPAD, 2 = EXTERNAL, 3 = REMOTE
Examples:
CONF:SETPT 0
SETPT 0
Query Syntax:
[CONFigure]:SETPT?
Returned Parameters: <NR1>
Related Commands: None
4.3.11 GPIB Communications Subsystem
4.3.11.1 GPIB:VERS? (Optional GPIB only)
This query reads the firmware version of the GPIB communication module.
Command Syntax:
none
Query Syntax:
[SYSTem][:COMMunicate]:GPIB:VERSion?
Parameters:
none
Examples:
SYST:COMM:GPIB:VERS?
GPIB:VERS?
80
Summary of Contents for DP SERIES II
Page 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Page 4: ......
Page 6: ...improper use of the equipment and accessories ii...
Page 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Page 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Page 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Page 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Page 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Page 53: ...Figure 3 15 Calibration 40...
Page 61: ...Figure 3 24 Calibration 48...
Page 63: ...Figure 3 25 a Local and b remote sensing 50...
Page 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Page 111: ...98...
Page 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Page 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Page 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Page 121: ...Figure 6 1 Block diagram 108...
Page 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Page 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Page 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...