3.6
Digital Input and Output Lines
All digital input and output control lines are connected to connector JS1 located on the rear
panel. The master and slave modules have identical connectors. As illustrated in figure 3.28, the
digital input lines are start, stop, clear, arm, and interlock set. Functionally, the first four digital
input control lines emulate the functions on the front panel when external control is enabled.
Enabling external control and external interlock is described in Section 3.1.1.3 and 3.1.2.2 for
DPD and DPA Series power supplies, respectively.
Figure 3.28 Digital input control lines
Interlock set requires a either a physical short between terminals 26 and 37 of connector JS1 or
application of a 5.0 V source with the positive connection at terminal 37 of JS1 and the negative
connection at terminal 7 of JS1. One of these two connections must be made to enable operation
of the power supply. If the interlock connection is broken then the loc (interlock) LED lights
and the power supply shuts off. As illustrated, digital control lines may be paralleled with other
supplies to allow simultaneous control.
Digital output control lines provide the means to monitor diagnostic functions as well as mode of
operation (voltage or current). All digital output control lines, as illustrated in Figure 3.29, are
connected to connector JS1. Refer to this figure for terminal identification. Each output
monitoring line can drive a 5.0 V, 5.0 mA load. An alarm condition will produce a 5.0 V output
at the respective terminal.
3.7
Diagnostic Functions
Diagnostic functions of the master and slave modules include thermal overload, interlock, power,
54
Summary of Contents for DP SERIES II
Page 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Page 4: ......
Page 6: ...improper use of the equipment and accessories ii...
Page 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Page 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Page 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Page 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Page 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Page 53: ...Figure 3 15 Calibration 40...
Page 61: ...Figure 3 24 Calibration 48...
Page 63: ...Figure 3 25 a Local and b remote sensing 50...
Page 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Page 111: ...98...
Page 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Page 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Page 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Page 121: ...Figure 6 1 Block diagram 108...
Page 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Page 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Page 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...