Command Syntax:
*SRE <NR1>
Example:
*SRE 20
Query Syntax:
*SRE?
Return Parameter:
<NR1> (Register value)
Related Commands: *ESE, *ESR
Table 4.6 SERVICE REQUEST ENABLE REGISTER
BIT POS.
WEIGHT
ABBREVIATION
DESCRIPTION
0
1
NU
Not Used
1
2
NU
Not Used
2
4
NU
Not Used
3
8
NU
Not Used
4
16
MAV
Message Available
5
32
ESB
Event Status Bit
6
64
NU
Not Used
7
128
NU
Not Used
4.5.6
Read Model Number, Part Number, and Serial Number
This query requests the power supply to identify itself. It returns a string composed of three fields
separated by commas.
Query Syntax:
*IDN?
Returned Parameters: Company Name, Power Supply Model, S/N (string format)
Example:
Magna-Power Electronics, Inc., DPD16-900, S/N: 1163-0361, F/W:1.0
Related Commands: CALibrate:IDN (Refer to Section 4.3.9.1, Calibrate Subsystem, for
information on configuring the DP Series power supply.)
4.5.7
Save
This command stores the present state of the power supply at the specified location in memory.
Data can be saved in 100 memory locations. The following power supply parameters are stored by
*SAV:
VOLT[:LEV][:IMM]
CURR[:LEV][:IMM]
VOLT:PROT[:LEV]
93
Summary of Contents for DP SERIES II
Page 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Page 4: ......
Page 6: ...improper use of the equipment and accessories ii...
Page 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Page 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Page 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Page 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Page 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Page 53: ...Figure 3 15 Calibration 40...
Page 61: ...Figure 3 24 Calibration 48...
Page 63: ...Figure 3 25 a Local and b remote sensing 50...
Page 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Page 111: ...98...
Page 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Page 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Page 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Page 121: ...Figure 6 1 Block diagram 108...
Page 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Page 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Page 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...