Caution: water cooled power supplies are not water tight. Allowing water
penetration is a safety hazard and will damage the power supply.
Each master/slave module has a 1/4" NPT female inlet and outlet for water flow. External
plumbing interconnects power supply modules. A minimum of 2.50" is recommended behind
the enclosure for this hardware and user connections. For systems requiring more than one
power supply, plumbing connections must be paralleled; that is, water should not flow from one
power supply into another.
2.2
AC Input Connections
Caution: disconnect AC power from the mains before attempting any
installation procedure.
Caution: a safety ground wire must be connected to the unit as indicated by
the protective ground symbol at the rear of the power supply.
AC power is wired to the power supply by attaching three cables plus ground for 3-phase
installations and two cables and ground for single phase installations. The manufacture
recommends cables, as specified in Tables 2.1 or 2.2, be crimped to ring terminals and securely
fastened to the four studs at the rear of the power supply. After connections are made, screw the
four standoffs into the back panel and place the protective shield over the connections.
This power supply is designed to be permanently connected to the power source requiring a
readily accessible disconnect device incorporated into the fixed wiring.
2.3
DC Output Connections
Caution: disconnect AC power from the mains before attempting any
installation procedure.
18
Summary of Contents for DP SERIES II
Page 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Page 4: ......
Page 6: ...improper use of the equipment and accessories ii...
Page 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Page 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Page 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Page 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Page 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Page 53: ...Figure 3 15 Calibration 40...
Page 61: ...Figure 3 24 Calibration 48...
Page 63: ...Figure 3 25 a Local and b remote sensing 50...
Page 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Page 111: ...98...
Page 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Page 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Page 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Page 121: ...Figure 6 1 Block diagram 108...
Page 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Page 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Page 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...