a.
Bits per second to 9600.
b.
Data bits to 8.
c.
Parity to None.
d.
Stop Bits to 1.
e.
Flow control to None.
5.
Click the OK button.
6.
On the menu bar, select File, Properties to open the Properties dialog box.
7.
Click on the Settings tab, and click the ASCII Setup button.
8.
On the ASCII Setup dialog box, set the following:
a.
Send line ends with line feeds.
b.
Echo typed characters locally.
c.
Append line feeds to incoming line ends.
9.
Press the OK button to close the ASCII Setup dialog box.
10.
Press the OK button to close the Properties dialog box.
D.3
485DSS Address Command
A command is required to address each individual 485DSS module. Once addressed, the
module will transparently convert serial data. The address command can only be
transmitted at 9600 baud, and if the command is transmitted at any other baud rate, the
command will be ignored by the 485DSS module. The address command has the following
form: Xoff character, the most significant address character, the least significant address
character, and SOH character. Xoff and SOH require a combination of keys to produce the
desired character in HyperTerminal. Simultaneously pressing the Ctrl key and the S key
(Ctrl+S) will produce the Xoff character and simultaneously pressing the Ctrl key and the A
key (Ctrl+A) will produce the SOH character. The address range of the 485DSS module is
from 0 to 255 in decimal or 0 to FF in hex. With HyperTerminal all addresses must be
entered as hex.
For an example, to set a 485DSS module with an address of 8F in hex (143 in decimal), the
address command is: Xoff 8 F SOH. To enter this data into HyperTerminal, the key
sequence is Ctrl+S, 8 key, F key and Ctrl+A. If the address is less than 10 hex, a leading
zero is required.
D.4
485DSS Communications using HyperTerminal
This section covers RS485 communications to the power supply using the HyperTerminal
and the 485DSS.
1.
Configure the power supply for remote operation.
2.
Set the address of the 485DSS module using the procedure in the previous section.
The SEL LED should light.
3.
On the menu bar in HyperTerminal, press Call, Disconnect.
4.
On the menu bar in HyperTerminal, press File, Properties to open the Properties
dialog box.
130
Summary of Contents for DP SERIES II
Page 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Page 4: ......
Page 6: ...improper use of the equipment and accessories ii...
Page 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Page 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Page 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Page 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Page 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Page 53: ...Figure 3 15 Calibration 40...
Page 61: ...Figure 3 24 Calibration 48...
Page 63: ...Figure 3 25 a Local and b remote sensing 50...
Page 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Page 111: ...98...
Page 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Page 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Page 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Page 121: ...Figure 6 1 Block diagram 108...
Page 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Page 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Page 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...