![Moxa Technologies IEF-G9010 Series User Manual Download Page 47](http://html1.mh-extra.com/html/moxa-technologies/ief-g9010-series/ief-g9010-series_user-manual_1841892047.webp)
IEF-G9010 Series User Manual
47
a.
Protocol Filter Profile Name
: Enter a name for the profile.
b.
(Optional)
Description
: Enter a description for the profile.
3.
In the [ICS Protocol] pane, select the protocols you want to include in the protocol filter.
a.
Click [Settings] next to a protocol, and select one of the following:
i.
Any
: Specify all available commands or function access in this protocol.
ii.
Basic
: Multiple selections of the following:
Read Only
: Read commands sent from HMI (Human-Machine Interface) / EWS (Engineering
Work Station) / SCADA (Supervisory Control and Data Acquisition) to PLC (Programmable Logic
Controller).
Read/Write
: Read and write commands sent from HMI/EWS/SCADA to PLC.
Admin Config
: Firmware update commands sent from EWS to PLC, Project update (i.e., PLC
code download) commands sent from EWS to PLC, and administration configuration relevant
commands from EWS to PLC.
Others
: Private commands, un-documented commands, or particular protocols provided by an
ICS vendor.
b.
Select the [S7Comm] protocol to configure advanced settings for this protocol:
i.
Click [Settings] besides [S7Comm] and select [Advanced Matching Criteria].