AirWorks AWK-3121 User’s Manual
Other Console Configurations
5-4
6.
The AWK-3121’s device information and Main Menu will be displayed. Please follow the
description on screen and select the administration option you wish to perform.
NOTE
To modify the appearance of the PComm Terminal Emulator window, select
Edit
Æ
Font
and
then choose the desired formatting options.
ATTENTION
If you unplug the RS-232 cable or trigger
DTR
, a disconnection event will be evoked to enforce
logout for network security. You will need to log in again to resume operation.
Configuration by Telnet and SSH Consoles
You may use Telnet or SSH client to access the AWK-3121 and manage the console over a
network. To access the AWK-3121’s functions over the network from a PC host that is connected
to the same LAN as the AWK-3121, you need to make sure that the PC host and the AWK-3121
are on the same logical subnet. To do this, check your PC host’s IP address and subnet mask.
NOTE
The AWK-3121’s default IP address is
192.168.127.253
and the default subnet mask is
255.255.255.0
(for a Class C network). If you do not set these values properly, please check the
network settings of your PC host and then change the IP address to 192.168.127.xxx and subnet
mask to 255.255.255.0.