AirWorks AWK-3121 User’s Manual
Introduction
1-4
Alarm Contact
1 relay output (capacity: 1A @24VDC)
Digital Input
2 electrically-isolated inputs
‧
+3 to -30V for state “0” (OFF)
‧
13 to 30V for state “1” (ON)
‧
Max. input current: 8 mA
Console
RS-232 (RJ45 type)
LAN Port
10/100BaseT(X) auto negotiation speed
LED Indicators
PWR1, PWR2, PoE, FAULT, STATE, Signal Strength,
CLIENT MODE, BRIDGE MODE, WLAN, 10M, 100M
Power
Input Voltage
12 to 48 VDC, redundant dual DC power inputs or
48 VDC Power-over-Ethernet (IEEE 802.3af)
Input Current
0.494 to 0.121 A (@ 12 to 48 VDC)
Input Current (@ 24VDC)
0.3 A
Overload Current Protection 1.6 A
Reverse Polarity Protection
Present
Mechanical
Dimensions
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight 850
g
Installation
DIN-rail, or Wall Mounting (with optional wall mounting kit)
Casing
IP30 protection, aluminum case
Environment
Operating Temperature:
Standard models: 0 to 60°C (32 to 140°F)
Wide Temp Models: -40 to 75°C (-40 to 167°F)
Storage Temperature:
-40 to 85ºC (-40 to 185ºF)
Ambient Relative Humidity
5 to 95% (non-condensing)
Regulatory Approvals*
Safety: EN60950-1,
UL60950-1
Radio:
EN300 328, EN301 893, ARIB STD-33/T66/T71 (Japan)
EMC:
EN301 489-1/-17, FCC Part 15, EN55022/55024, IEC61000-6-2/-4
Environmental/EMC
compliancy
EN50155, EN50121-1/-4
* Please check Moxa
’
s website for the most up-to-date certification status.
Warranty
5 years
Details: See
http://www.moxa.com/warranty
ATTENTION
The AWK-3121 is NOT a portable mobile device and should be located at least 20 cm away from
the human body.
The AWK-3121 is NOT designed for the general public. To deploy AWK-3121 units and establish
a wireless network safely, a well-trained technician is required for installation.