MC40 Integrator Guide
–
Verify Check Digit
- Enable this feature to check the integrity of all Code 39 symbols to verify that the data
complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols
that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43
check digit (default - disabled).
–
Report Check Digit
- Transmit Code 39 data with or without the check digit. A check in the checkbox
indicates to send Code 39 data with check digit (default - disabled).
–
Full ASCII
- Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII
character set. To enable or disable Code 39 Full ASCII (default - disabled),
–
Redundancy
- Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
–
Convert Code39 To Code32
- Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.
Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 (default - disabled).
–
Report Code32 Prefix
- Scan the appropriate bar code to enable or disable adding the prefix character
“A” to all Code 32 bar codes (default - disabled).
–
Security Level
- Options:
Security level 0
,
Security Level 1
,
Security Level 2
and
Security Level 3
(default - Security level 1).
•
Interleaved 2 of 5
–
Length1
- Use to set decode lengths (default - 14). See
for more information.
–
Length2
- Use to set decode lengths (default - 10). See
for more information.
–
Redundancy
- Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
–
Check Digit
♦
No Check Digit
- A check digit is not used. (default)
♦
USS Check Digit
- Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
♦
OPCC Check Digit
- Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
–
Report Check Digit
- Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send Interleaved 2 of 5 data with check digit (default - disabled).
–
Convert ITF-14 To EAN13
- Convert 14-character Interleaved 2 of 5 bar codes to EAN-13, and transmit as
EAN-13. The Interleaved 2 of 5 bar code must be enabled and must have a leading zero and a valid EAN-13
check digit. A check in the checkbox indicates that the option is enabled (default - disabled).
•
Composite AB
–
UCC Link Mode
♦
Link Flag ignored
- 1D component is transmitted regardless of whether a 2D component is detected.
♦
Always Linked
- 1D and the 2D components are transmitted. If 2D is not present, the 1D component is
not transmitted.
♦
Auto Discriminate
- the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
•
UK Postal
–
Report Check Digit
- Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).
•
Codabar
–
Length1
- Use to set decode lengths (default - 6). See
for more information.
4-12