FIELD LEVEL TEST MODES AND PROCEDURES: Required Test Equipment
8-2
68P80400P94-O
The following tests are performed in Test Mode:
•
TX Power Test
•
BER Tests
800BER1
800BER2
800BER3
800BER4
900BER1
900BER2
900BER3
NOTE:
The Power, MPX, and MOD test parameters are for factory use only and should not
be adjusted by field service personnel. The default values for these parameters are
as follows:
•
Power: 0 dB
•
MPX: 1:6
•
MOD: QAM16
8.2
Required Test Equipment
Use the following list to identify the test equipment required to perform the technician tests.
Refer to the appendix for test equipment part numbers and descriptions.
•
Battery eliminator
•
Data cable RS232 or USB data cable
•
R-2660 Digital Communications System Analyzer
•
RF Adapter
•
Variable 5.0 to 12.0 Vdc power supply (3.0 A capability)
8.3
Field-Level Test Checklist
Use the following test checklist to ensure that all the necessary tests are performed and to
provide a tracking mechanism in case the unit is sent to the next level of service.
Check the appropriate box for each test performed and indicate whether or not the test was
completed successfully.