![Motorola i760 Field Service Manual Download Page 30](http://html.mh-extra.com/html/motorola/i760/i760_field-service-manual_242952030.webp)
DISPLAYS, MESSAGES, AND ALERTS: Power-Down Sequence
3-2
68P80400P94-O
3.2
Power-Down Sequence
To power down the unit, press and hold the Power key until the unit begins powering down.
3.3
Messages
3.3.1
Self-Test Errors
The following table contains the list of self-test non-reset errors. These errors are displayed as SELF
CHECK ERROR YXXXX (YXXXX represents the identifier for that error).
3.3.2
Self-Test Reset Errors
The following table contains the list of self-test reset errors. These errors are displayed as SELF
CHECK FAIL YXXXX (YXXXX represents the identifier for that error).
Table 3-1. Self-Test Errors
Y
XXXX
Description of Error
0
0001
Non-reset error log
0
0002
Codeplug error log
Table 3-2. Self-Test Reset Errors
Y
XXXX
Description of Error
0
0100
RAM failure
0
0200
Data lines failure
0
0400
Address line failure
0
0800
Codeplug corruption/invalid
0
1000
Flash checksum error
0
2000
Reset error logging
0
4000
Codeplug mismatch
F
4000
Ergo pre-self-test codeplug error
F
8000
Ergo pre-self-test invalid device or device failure
F
8002
Ergo pre-self-test invalid device or device failure
:
0800
FDI-related error