BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures
68P80400P94-O
6-5
12. Press the
Stop
key to end the test.
6.2.2
ESN and IMEI Matching Test
Use this test to verify that the electronic serial number (ESN) matches the International
Mobile Equipment Identifier (IMEI) on the Serial Number label located on the chassis of the
unit.
The ESN/IMEI Matching test time is approximately 6 minutes:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
2. Enter Debug Mode. The
Unit Info
display appears.
3. Scroll down until the
IMEI/SIM ID
choice is highlighted, then press
View
to view the
IMEI/SIM ID
display.
4. Write down the digits shown in the IMEI line.
5. Verify that this number matches the IMEI on the Serial Number label. The last zero on
the label will be missing.
If the numbers do not match, send the unit to the field level of service.
6.2.3
Debug Check
Use this check to monitor (measure) the data in an i850/i760 unit.
NOTE:
The following procedure describes the sequence of displays accessed via the down
scroll key. If you press the up scroll key, the sequence appears in reverse order.
To monitor the data in the unit:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
2. Enter Debug Mode. The
Unit Info
display appears.
a.
Press
View
to view the
Phone Model
display, and then press
Select
to view the
phone model, such as i850/i760.
b.
Press
Back
to return to the
Unit Info
display, and then scroll down (down scroll key)
to highlight the
CP Ver
choice.
c.
Press
Select
to view the Codeplug Version. The first half of the line displays the
codeplug structure and default version; the second half displays the codeplug
bandmap.
d. Press
Back
to return to the
Unit Info
display, and then scroll down to highlight the
CSD Ver
choice.
e.
Press
Select
to view the Customer Static Data version. The first number indicates the
customer. The second number indicates the structure revision. The third number
indicates the data revision.
Summary of Contents for i760
Page 22: ...OVERVIEW SIM Cards 1 8 68P80400P94 O ...
Page 36: ...This page intentionally left blank ...
Page 38: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 71: ...PREPARING FOR FIELD LEVEL TESTING Back Housing 68P80400P94 O 7 9 Figure 7 5 Figure 7 6 ...