BASIC LEVEL TEST MODES AND PROCEDURES: Test Modes
68P80400P94-O
6-3
6.1.3
Entering Test Mode
Use this procedure to access Test Mode.
To enter Test Mode:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
NOTE:
Steps 2 through 7 must be performed quickly with no more than one second between each
key press: (
#,*, M, M, M, <, M, M, <
)
2. Press
#
.
3. Press
*
.
IMEI/SIM ID/SN
Displays the electronic serial number, SIM ID serial number, and unit serial number.
The IMEI is the global name assigned to the mobile station at manufacturing time and should
correspond to the serial-number tag of the unit.
The SIM ID is the SIM electronic serial number and should correspond with the number
stamped on the SIM card. The SN is applied during manufacturing.
Pressing
OK
allows the IMEI/SIM ID to be traced.
Registratiion Log
Displays the Dispatch Log, Interconnect Log, Packet Data Log, Mobile IP Log, and Phone
Rst Log. Registration Log information is updated when the user deselects and selects the
Registration Log choice.
Err/Channel
Displays the physical channel that the unit is connected to or the radio link procedure that is
currently active. Also, displays error codes encountered during normal operation if Err/
Channel is On. At power up, Err/Channel is Off.
Current Freq
Displays current frequency and band. Pressing
OK
allows the current frequency and band to
be traced.
Dispatch IDs
Displays the Dispatch Group ID affiliated with the unit in the current dispatch-location area.
Also, displays the Dispatch Individual ID affiliated with the unit in the current dispatch
location. Pressing
OK
allows the dispatch IDs to be displayed periodically.
Band Info
Displays primary and secondary bands.
Bandmap
Displays the currently selected regional bandmap. Pressing
OK
allows the bandmap to be
displayed periodically.
Hardware
Displays the AFC Offset and Channel Number.
Pressing
OK
allows the hardware parameters to be traced.
Fatal Err/#
Displays the Fatal Error log. This log contains a count of any fatal errors logged during the
unit's automatic self test. Optioning clear empties the log.
Flags:
Displays the error log. This log contains any errors logged by the unit software. Pressing
Menu
when it appears displays the Clearall screen in which the user can clear all the logged
errors.
Resets:
Displays the Reset Error log. This log contains any errors logged when the user resets the
unit during operation. The most recent reset appears at the top of the list. Pressing
Menu
when it appears displays the Clearall screen in which the user can clear all the logged errors.
CE Status
Indicates accessory type connected to unit.
Table 6-1. Display Screens (Continued)
Name
Description